TodayToday's edition
67 specs listed, 57 of them differ. Each value is the maker's own; nothing is converted or scored.
| Field | Supermicro Supermicro SYS-121C-TN2R | Supermicro Supermicro Gold Series SYS-222H-TN |
|---|---|---|
| Maker | Supermicro | Supermicro |
| Category | Servers | Servers |
| List price | no list price | no list price |
| Availability | not stated | not stated |
| Life cycle | Not stated | Not stated |
| Launch | Not stated | Not stated |
| Part number | SYS-121C-TN2R | SYS-222H-TN |
| First seen | Nov 3 | Nov 3 |
| Last change | Nov 3 | Nov 3 |
| Specs, as each maker lists them | ||
| CPU | Dual Socket E (LGA-4677), 5th Gen Intel® Xeon® / 4th Gen Intel® Xeon® Scalable processors | Dual Socket E2 (LGA-4710), Intel® Xeon® 6700/6500 series processors with P-cores or 6700 series processors with E-cores |
| Memory | Slot Count: 16 DIMM slots, Max Memory (1DPC): Up to 4TB 5600MT/s ECC DDR5 RDIMM | Slot Count: 32 DIMM slots, Max Memory (1DPC): Up to 4TB 6400MT/s ECC DDR5 RDIMM, Max Memory (1DPC): Up to 1TB 8000MT/s ECC DDR5 MRDIMM (P-core only), Max Memory |
| BIOS Type | AMI 32MB SPI FLASH ROM | AMI 64MB SPI Flash |
| Core Count | Up to 36C/72T; Up to 82.5MB Cache per CPU | P-cores: Up to 86C/172T; Up to 336MB Cache per CPU | E-cores: Up to 144C/144T; Up to 108MB Cache per CPU |
| Motherboard | Super X13DDW-A | Super X14DBM-SP |
| Max GPU Count | Up to 2 single-width GPUs | Up to 4 double-width or 8 single-width GPUs |
| Supported GPU | NVIDIA PCIe: A2, L4; Intel PCIe: Intel Data Center GPU Flex 140 | NVIDIA PCIe: H100 NVL, A1000, A16, L4, L40S, NVIDIA RTX PRO™ 4000 Blackwell, NVIDIA RTX PRO™ 4500 Blackwell, NVIDIA RTX PRO™ 4500 Blackwell Server Edition, NVID |
| Memory Voltage | 1.1V | 1.1V |
| Processor Note | Supports up to 270W TDP CPUs (Air Cooled)*, *Air Cooled CPUs with TDP over 250W only supported under specific conditions. Contact a Supermicro representative fo | Supports up to 350W TDP CPUs (Air Cooled), Supports up to 350W TDP CPUs (Liquid Cooled) |
| Chassis - Model | CSE-LB13TS-R0AWNP2 | CSE-HS219-R000NP |
| Front Panel - LED | Drive activity, Network activity, Power status, Universal Information | HDD activity, LAN1 activity, LAN2 acticity, Power Fail, Power status, System information (overheat/UID) |
| Operating Systems | ESXi 7.0 U3, ESXi 8.0, Hypervisor 8.2.1, Oracle Linux 8.10, Oracle Linux 9.0, RHEL 8.7, RHEL 9.0, SLES 12 SP5, SLES 15 SP4, Windows Server 2022, Windows Server | ESXi 8.0 U3, ESXi 9.0, Oracle Linux 9.4, RHEL 9.4, RHEL 10.0, SLES 16.0, Ubuntu 24.04 LTS, Windows Server 2022, Windows Server 2025 |
| Security - Features | Cryptographically Signed Firmware, Secure Boot, Secure Firmware Updates, Automatic Firmware Recovery, Supply Chain Security: Remote Attestation, Runtime BMC Pro | Cryptographically Signed Firmware, Secure Boot, Secure Firmware Updates, Automatic Firmware Recovery, Supply Chain Security: Remote Attestation, Runtime BMC Pro |
| Security - Hardware | Trusted Platform Module (TPM) 2.0, Silicon Root of Trust (RoT) – NIST 800-193 Compliant | Trusted Platform Module (TPM) 2.0, Silicon Root of Trust (RoT) – NIST 800-193 Compliant |
| Default Power Supply | 2x 860W Redundant (1 + 1) Titanium Level (96%) Hot-plug power supplies | 2x 1200W Redundant (1 + 1) Titanium Level (96%) Hot-plug power supplies |
| Input / Output - LAN | 1 RJ45 1 GbE Dedicated BMC LAN port | 1 RJ45 1 GbE Dedicated BMC LAN port |
| Input / Output - TPM | 1 TPM header | Not listed |
| Input / Output - USB | 2 USB 3.2 Gen1 Type-A ports (rear) | 2 USB 3.2 Gen1 ports (Header), 2 USB 3.2 Gen1 ports (Rear) |
| Chassis - Form Factor | 1U Rackmount | 2U Rackmount |
| Front Panel - Buttons | Power On/Off, Reset button, Unit Identifier (UID) | Power On/Off, UID button |
| Management - Software | SuperCloud Composer® (SCC), Supermicro Server Manager (SSM), Supermicro Update Manager (SUM), Supermicro SuperDoctor® 5 (SD5), Super Diagnostics Offline (SDO), | SuperCloud Composer® (SCC), Supermicro Server Manager (SSM), Super Diagnostics Offline (SDO), Supermicro Thin-Agent Service (TAS), SuperServer Automation Assist |
| System Cooling - Fans | Up to 6x 4cm heavy duty fans with optimal fan speed control | Up to 4x 8cm heavy duty fans with optimal fan speed control |
| Input / Output - Video | 1 VGA port | 1 VGA port |
| Input / Output - Serial | 1 COM port (Rear) | Not listed |
| On-Board Devices - NVMe | NVMe; RAID 0/1/5/10 support(VROC HW key required) | NVMe; RAID 0/1/5/10 support(Intel® VROC RAID key required) |
| On-Board Devices - SATA | SATA (6Gbps); RAID 0/1/5/10 support | Not listed |
| Drive Bays / Storage - M.2 | 2 M.2 PCIe 5.0 x4 NVMe slots (M-key 2280(default); VROC required for RAID) | 2 M.2 PCIe 5.0 x2 NVMe slots (M-key 2280/22110) |
| PC Health Monitoring - CPU | 8 Phase-switching voltage regulator; Monitors for CPU Cores, Chipset Voltages, Memory. | Monitors for CPU Cores, Chipset Voltages, Memory |
| PC Health Monitoring - Fan | Fans with tachometer monitoring, Pulse Width Modulated (PWM) fan connectors, Status monitor for speed control | Fans with tachometer monitoring, Pulse Width Modulated (PWM) fan connectors, Status monitor for speed control |
| Default Power Supply - +12V | Max: 66.67A / Min: 0A (100Vac-127Vac), Max: 71.67A / Min: 0A (Vdc-240Vdc), Max: 71.67A / Min: 0A (200Vac-240Vac) | Max: 66.7A / Min: 0A (100Vac-127Vac), Max: 100A / Min: 0A (200Vac-240Vac), Max: 100A / Min: 0A (230Vdc-240Vdc) (for CCC only) |
| System Cooling - Air Shroud | 2 Air Shrouds | 2 Air Shrouds |
| Default Power Supply - 5V SB | Max: 4A / Min: 0A | Not listed |
| Default Power Supply - Input | 800W: 100-127Vac / 50-60Hz, 860W: 200-240Vac / 50-60Hz, 860W: 240Vdc / 50-60Hz | 800W: 100-127Vac / 50-60Hz, 1200W: 200-240Vac / 50-60Hz, 1200W: 230-240Vdc / 50-60Hz (for CCC only) |
| Operating Environment - RoHS | RoHS Compliant | Not listed |
| Management - Power configurations | ACPI/APM Power Management | Power-on mode for AC power recovery, ACPI Power Management |
| Default Power Supply - Output Type | Backplanes (gold finger) | Backplanes (gold finger) |
| PC Health Monitoring - Temperature | Monitoring for CPU and chassis environment, Thermal Control for fan connectors | Monitoring for CPU and chassis environment, Thermal Control for fan connectors |
| Chassis Dimensions and Weight - Depth | 23.5" (597 mm) | 29.73" (755.2 mm) |
| Chassis Dimensions and Weight - Width | 17.2" (437 mm) | 17.3" (438.4 mm) |
| Chassis Dimensions and Weight - Height | 1.7" (43 mm) | 3.5" (88 mm) |
| Chassis Dimensions and Weight - Weight | Gross Weight: 40 lbs (18.1 kg), Net Weight: 25 lbs (11.3 kg) | Gross Weight: 66 lbs (30 kg), Net Weight: 40 lbs (18.2 kg) |
| Drive Bays / Storage - Peripheral Bays | 1 slim DVD bay (optional) | Not listed |
| Chassis Dimensions and Weight - Package | 7.8" (H) x 23.8" (W) x 32.4" (D) | 10.12" (H) x 23.82" (W) x 37.28" (D) |
| On-Board Devices - Network Connectivity | Via AIOM | Via AIOM |
| Default Power Supply - Dimension (WxHxL) | 54.5 x 40.25 x 322 mm | 73.5 x 40 x 265 mm |
| Operating Environment - Environmental Spec. | Name: A2 | Operating Temperature: 10°C to 35°C (50°F to 95°F) | Non-operating Temperature: -30°C to 60°C (-40°F to 140°F) | Operating Relative Humidity: 8% to 8 | Not listed |
| Chassis Dimensions and Weight - Available Color | Black front & silver body | Silver |
| Drive Bays / Storage - Drive Bays Configuration | Default: Total 8 bays; 2 front hot-swap 2.5" NVMe*/SAS*/SATA* drive bays, 6 front hot-swap 2.5" SAS*/SATA* drive bays | (*NVMe/SAS/SATA support may require addi | Default: Total 8 bays; 8 front hot-swap 2.5" NVMe*/SAS*/SATA* drive bays | Option A: Total 16 bays; 16 front hot-swap 2.5" NVMe*/SAS*/SATA* drive bays | Option |
| Expansion Slots - PCI-Express (PCIe) Configuration | Default: 2 PCIe 5.0 x16 FHHL slots, 2 PCIe 5.0 x16 AIOM slots (OCP 3.0 compatible) | Option A*: 4 PCIe 5.0 x16 FH/10.5"L double-width slots, 1 PCIe 5.0 x16 AIOM slot (OCP 3.0 compatible), 1 PCIe 5.0 x8 AIOM slot (OCP 3.0 compatible); Option B*: |
| Optional Power Supply 1 | Not listed | 2x 2000W Redundant (1 + 1) Titanium Level (96%) Hot-plug power supplies |
| Optional Power Supply 2 | Not listed | 2x 1600W Redundant (1 + 1) Titanium Level (96%) Hot-plug power supplies |
| Optional Power Supply 3 | Not listed | 2x 2600W Redundant (1 + 1) Titanium Level (96%) Hot-plug power supplies |
| Default Power Supply - 12V SB | Not listed | Max: 2.1A / Min: 0A |
| Expansion Slots - CXL Support | Not listed | Up to 4 CXL 2.0 x16/x8 devices |
| Optional Power Supply 1 - +12V | Not listed | Max: 83.3A / Min: 0A (100Vac-120Vac), Max: 150A / Min: 0A (200Vac-220Vac), Max: 165A / Min: 0A (220Vac-230Vac), Max: 166.7A / Min: 0A (200Vac-240Vac) (for UL/cU |
| Optional Power Supply 2 - +12V | Not listed | Max: 83.3A / Min: 0A (100Vac-127Vac), Max: 133.3A / Min: 0A (200Vac-240Vac) |
| Optional Power Supply 1 - Input | Not listed | 1000W: 100-120Vac / 50-60Hz, 1800W: 200-220Vac / 50-60Hz, 1980W: 220-230Vac / 50-60Hz, 2000W: 230-240Vac / 50-60Hz, 2000W: 200-240Vac / 50-60Hz (for UL/cUL only |
| Optional Power Supply 2 - Input | Not listed | 1000W: 100-127Vac / 50-60Hz, 1600W: 200-240Vac / 50-60Hz, 1600W: 200-240Vdc / 50-60Hz (for CQC only) |
| System Cooling - Liquid Cooling | Not listed | Direct to Chip (D2C) Cold Plate (optional) |
| Optional Power Supply 1 - 12V SB | Not listed | Max: 2.1A / Min: 0A |
| Optional Power Supply 2 - 12V SB | Not listed | Max: 3.5A |
| Optional Power Supply 1 - Output Type | Not listed | Backplanes (gold finger) |
| Optional Power Supply 2 - Output Type | Not listed | Backplanes (gold finger) |
| Optional Power Supply 1 - Certification | Not listed | Titanium Level, [ Test Report ] |
| Optional Power Supply 1 - Dimension (WxHxL) | Not listed | 73.5 x 40 x 265 mm |
| Optional Power Supply 2 - Dimension (WxHxL) | Not listed | 73.5 x 40 x 265 mm |
| Optional Power Supply 3 - Dimension (WxHxL) | Not listed | 73.5 x 40 x 265 mm |
Shaded rows differ. Rows are matched by their label, so two makers' names for the same figure can sit on separate rows; hover a value to see its maker's own label where it differs.