| Field | Supermicro Supermicro Gold Series SYS-222H-TN | Supermicro Supermicro SYS-F610P2-RTN |
|---|---|---|
| Maker | Supermicro | Supermicro |
| Category | Servers | Servers |
| List price | no list price | no list price |
| Availability | not stated | not stated |
| Life cycle | Not stated | Not stated |
| Launch | Not stated | Not stated |
| Part number | SYS-222H-TN | SYS-F610P2-RTN |
| First seen | Nov 3 | Nov 3 |
| Last change | Nov 3 | Nov 3 |
| Specs, as each maker lists them | ||
| CPU | Dual Socket E2 (LGA-4710), Intel® Xeon® 6700/6500 series processors with P-cores or 6700 series processors with E-cores | Dual Socket P+ (LGA-4189), 3rd Gen Intel® Xeon® Scalable processors |
| Memory | Slot Count: 32 DIMM slots, Max Memory (1DPC): Up to 4TB 6400MT/s ECC DDR5 RDIMM, Max Memory (1DPC): Up to 1TB 8000MT/s ECC DDR5 MRDIMM (P-core only), Max Memory | Slot Count: 16 DIMM slots, Max Memory (2DPC): Up to 2TB non-ECC DDR4, Supports Intel® Optane™ persistent memory 200 series |
| BIOS Type | AMI 64MB SPI Flash | AMI 32MB SPI FLASH ROM |
| Core Count | P-cores: Up to 86C/172T; Up to 336MB Cache per CPU | E-cores: Up to 144C/144T; Up to 108MB Cache per CPU | Up to 36C/72T; Up to 54MB Cache per CPU |
| Motherboard | Super X14DBM-SP | Super X12DPFR-AN6 |
| Max GPU Count | Up to 4 double-width or 8 single-width GPUs | Not listed |
| Supported GPU | NVIDIA PCIe: H100 NVL, A1000, A16, L4, L40S, NVIDIA RTX PRO™ 4000 Blackwell, NVIDIA RTX PRO™ 4500 Blackwell, NVIDIA RTX PRO™ 4500 Blackwell Server Edition, NVID | Not listed |
| Memory Voltage | 1.1V | 1.2V |
| Processor Note | Supports up to 350W TDP CPUs (Air Cooled), Supports up to 350W TDP CPUs (Liquid Cooled) | Supports up to 185W TDP CPUs (Air Cooled) |
| Chassis - Model | CSE-HS219-R000NP | CSE-F418BC3-R2K20BP |
| Front Panel - LED | HDD activity, LAN1 activity, LAN2 acticity, Power Fail, Power status, System information (overheat/UID) | HDD activity LED, Network activity LEDs, Power status LED, Universal Information (UID) LED |
| Operating Systems | ESXi 8.0 U3, ESXi 9.0, Oracle Linux 9.4, RHEL 9.4, RHEL 10.0, SLES 16.0, Ubuntu 24.04 LTS, Windows Server 2022, Windows Server 2025 | ESXi 7.0 U3, RHEL 8.2, RHEL 9.0, SLES 12 SP5, SLES 15 SP2 |
| Security - Features | Cryptographically Signed Firmware, Secure Boot, Secure Firmware Updates, Automatic Firmware Recovery, Supply Chain Security: Remote Attestation, Runtime BMC Pro | Cryptographically Signed Firmware, Secure Boot, Secure Firmware Updates, Automatic Firmware Recovery, System Lockdown |
| Security - Hardware | Trusted Platform Module (TPM) 2.0, Silicon Root of Trust (RoT) – NIST 800-193 Compliant | Trusted Platform Module (TPM) 2.0, Silicon Root of Trust (RoT) – NIST 800-193 Compliant |
| Default Power Supply | 2x 1200W Redundant (1 + 1) Titanium Level (96%) Hot-plug power supplies | 1x 2200W Redundant Titanium Level (96%) power supply |
| Input / Output - LAN | 1 RJ45 1 GbE Dedicated BMC LAN port | 1 RJ45 1 GbE Dedicated BMC LAN port |
| Input / Output - USB | 2 USB 3.2 Gen1 ports (Header), 2 USB 3.2 Gen1 ports (Rear) | 2 USB 3.0 ports (rear) |
| Chassis - Form Factor | 2U Rackmount | 4U Rackmount |
| Front Panel - Buttons | Power On/Off, UID button | Power On/Off button, UID button |
| Management - Software | SuperCloud Composer® (SCC), Supermicro Server Manager (SSM), Super Diagnostics Offline (SDO), Supermicro Thin-Agent Service (TAS), SuperServer Automation Assist | SuperCloud Composer® (SCC), Supermicro Server Manager (SSM), Supermicro Update Manager (SUM), Supermicro SuperDoctor® 5 (SD5), Super Diagnostics Offline (SDO), |
| System Cooling - Fans | Up to 4x 8cm heavy duty fans with optimal fan speed control | Up to 3x 4cm Fan(s) |
| Input / Output - Video | 1 VGA port | 1 VGA port |
| On-Board Devices - NVMe | NVMe; RAID 0/1/5/10 support(Intel® VROC RAID key required) | Not listed |
| Optional Power Supply 1 | 2x 2000W Redundant (1 + 1) Titanium Level (96%) Hot-plug power supplies | Not listed |
| Optional Power Supply 2 | 2x 1600W Redundant (1 + 1) Titanium Level (96%) Hot-plug power supplies | Not listed |
| Optional Power Supply 3 | 2x 2600W Redundant (1 + 1) Titanium Level (96%) Hot-plug power supplies | Not listed |
| Drive Bays / Storage - M.2 | 2 M.2 PCIe 5.0 x2 NVMe slots (M-key 2280/22110) | Not listed |
| PC Health Monitoring - CPU | Monitors for CPU Cores, Chipset Voltages, Memory | 4+1 Phase-switching voltage regulator; Monitors for CPU Cores, Chipset Voltages, Memory. |
| PC Health Monitoring - Fan | Fans with tachometer monitoring, Pulse Width Modulated (PWM) fan connectors, Status monitor for speed control | Fans with tachometer monitoring, Pulse Width Modulated (PWM) fan connectors, Status monitor for speed control |
| Default Power Supply - +12V | Max: 66.7A / Min: 0A (100Vac-127Vac), Max: 100A / Min: 0A (200Vac-240Vac), Max: 100A / Min: 0A (230Vdc-240Vdc) (for CCC only) | Max: 100A / Min: 0A (100Vac-127Vac), Max: 150A / Min: 0A (200Vac-220Vac), Max: 165A / Min: 0A (220Vac-230Vac), Max: 174.17A / Min: 0A (230Vac-240Vac), Max: 174. |
| System Cooling - Air Shroud | 2 Air Shrouds | 1 Air Shroud |
| Default Power Supply - Input | 800W: 100-127Vac / 50-60Hz, 1200W: 200-240Vac / 50-60Hz, 1200W: 230-240Vdc / 50-60Hz (for CCC only) | 1200W: 100-127Vac / 50-60Hz, 1800W: 200-220Vac / 50-60Hz, 1980W: 220-230Vac / 50-60Hz, 2090W: 230-240Vac / 50-60Hz, 2090W: 230-240Vdc / 50-60Hz (for CCC only), |
| Default Power Supply - 12V SB | Max: 2.1A / Min: 0A | Not listed |
| Expansion Slots - CXL Support | Up to 4 CXL 2.0 x16/x8 devices | Not listed |
| Optional Power Supply 1 - +12V | Max: 83.3A / Min: 0A (100Vac-120Vac), Max: 150A / Min: 0A (200Vac-220Vac), Max: 165A / Min: 0A (220Vac-230Vac), Max: 166.7A / Min: 0A (200Vac-240Vac) (for UL/cU | Not listed |
| Optional Power Supply 2 - +12V | Max: 83.3A / Min: 0A (100Vac-127Vac), Max: 133.3A / Min: 0A (200Vac-240Vac) | Not listed |
| Optional Power Supply 1 - Input | 1000W: 100-120Vac / 50-60Hz, 1800W: 200-220Vac / 50-60Hz, 1980W: 220-230Vac / 50-60Hz, 2000W: 230-240Vac / 50-60Hz, 2000W: 200-240Vac / 50-60Hz (for UL/cUL only | Not listed |
| Optional Power Supply 2 - Input | 1000W: 100-127Vac / 50-60Hz, 1600W: 200-240Vac / 50-60Hz, 1600W: 200-240Vdc / 50-60Hz (for CQC only) | Not listed |
| System Cooling - Liquid Cooling | Direct to Chip (D2C) Cold Plate (optional) | Not listed |
| Optional Power Supply 1 - 12V SB | Max: 2.1A / Min: 0A | Not listed |
| Optional Power Supply 2 - 12V SB | Max: 3.5A | Not listed |
| Management - Power configurations | Power-on mode for AC power recovery, ACPI Power Management | ACPI/APM Power Management |
| Default Power Supply - Output Type | Backplanes (gold finger) | Backplanes (gold finger) |
| PC Health Monitoring - Temperature | Monitoring for CPU and chassis environment, Thermal Control for fan connectors | Monitoring for CPU and chassis environment |
| Chassis Dimensions and Weight - Depth | 29.73" (755.2 mm) | 29" (737 mm) |
| Chassis Dimensions and Weight - Width | 17.3" (438.4 mm) | 17.63" (448 mm) |
| Optional Power Supply 1 - Output Type | Backplanes (gold finger) | Not listed |
| Optional Power Supply 2 - Output Type | Backplanes (gold finger) | Not listed |
| Chassis Dimensions and Weight - Height | 3.5" (88 mm) | 6.96" (177 mm) |
| Chassis Dimensions and Weight - Weight | Gross Weight: 66 lbs (30 kg), Net Weight: 40 lbs (18.2 kg) | Gross Weight: 200 lbs (90.71 kg), Net Weight: 150 lbs (68.04 kg) |
| Chassis Dimensions and Weight - Package | 10.12" (H) x 23.82" (W) x 37.28" (D) | 15" (H) x 28.3" (W) x 42.4" (D) |
| On-Board Devices - Network Connectivity | Via AIOM | 1 RJ45 1GbE |
| Optional Power Supply 1 - Certification | Titanium Level, [ Test Report ] | Not listed |
| Default Power Supply - Dimension (WxHxL) | 73.5 x 40 x 265 mm | 76 x 40 x 336 mm |
| Optional Power Supply 1 - Dimension (WxHxL) | 73.5 x 40 x 265 mm | Not listed |
| Optional Power Supply 2 - Dimension (WxHxL) | 73.5 x 40 x 265 mm | Not listed |
| Optional Power Supply 3 - Dimension (WxHxL) | 73.5 x 40 x 265 mm | Not listed |
| Chassis Dimensions and Weight - Available Color | Silver | Silver |
| Drive Bays / Storage - Drive Bays Configuration | Default: Total 8 bays; 8 front hot-swap 2.5" NVMe*/SAS*/SATA* drive bays | Option A: Total 16 bays; 16 front hot-swap 2.5" NVMe*/SAS*/SATA* drive bays | Option | Default: Total 6 bays; 6 front hot-swap 2.5" NVMe/SAS/SATA drive bays |
| Expansion Slots - PCI-Express (PCIe) Configuration | Option A*: 4 PCIe 5.0 x16 FH/10.5"L double-width slots, 1 PCIe 5.0 x16 AIOM slot (OCP 3.0 compatible), 1 PCIe 5.0 x8 AIOM slot (OCP 3.0 compatible); Option B*: | Default: 1 PCIe 4.0 x16 LP slot, 1 PCIe 4.0 x16 AIOM slot (OCP 3.0 compatible) |
| Default Power Supply - 5V SB | Not listed | Max: 1A / Min: 0A |
| Operating Environment - RoHS | Not listed | RoHS Compliant |
| Operating Environment - Environmental Spec. | Not listed | Operating Temperature: 10°C to 35°C (50°F to 95°F), Non-operating Temperature: -40°C to 60°C (-40°F to 140°F), Operating Relative Humidity: 5% to 95% (8), Non-o |