TodayToday's edition
49 specs listed, 35 of them differ. Each value is the maker's own; nothing is converted or scored.
| Field | Supermicro Supermicro SYS-120U-TNR | Supermicro Supermicro SYS-220HE-TNR |
|---|---|---|
| Part number | SYS-120U-TNR | SYS-220HE-TNR |
| Specs, as each maker lists them | ||
| Memory | Slot Count: 32 DIMM slots, Max Memory (2DPC): Up to 8TB 3200MT/s ECC DDR4 RDIMM/LRDIMM, Supports Intel® Optane™ persistent memory 200 series | Slot Count: 32 DIMM slots, Max Memory (2DPC): Up to 8TB 3200MT/s ECC DDR4 RDIMM/LRDIMM |
| BIOS Type | AMI 32MB SPI Flash EEPROM | Not listed |
| Core Count | Up to 40C/80T; Up to 60MB Cache per CPU | Not listed |
| Motherboard | Super X12DPU-6 | Super X12DHM-6 |
| Max GPU Count | Up to 2 double-width or 2 single-width GPUs | Up to 3 double-width or 3 single-width GPUs |
| Supported GPU | NVIDIA PCIe: A100, A16, A2, L4, T4 | NVIDIA PCIe: A10, A100, A40, T4 |
| Chassis - Model | CSE-119UH3TS-R1K22P-T | CSE-HE211-R000NFP |
| Front Panel - LED | HDD activity, LAN1 activity, Power status, System information (overheat/UID) | HDD activity LED, LAN1 activity, LAN2 activity, Power Fail, Power status LED, System information |
| Operating Systems | ESXi 6.7 U3, ESXi 7.0 U2, ESXi 8.0, Hypervisor 8.2, Oracle Linux 8.3, RHEL 7.9, RHEL 8.2, RHEL 9.0, SAP HANA 2.0, SLES 12 SP5, SLES 15 SP2, SLES 15 SP3, Windows | Windows Server 2019, Windows Server 2022 |
| Default Power Supply | 1x 1200W Redundant Titanium Level (96%) Hot-plug power supply | 1x 2000W Redundant Titanium Level (96%) power supply |
| Enterprise Solutions | VMWare vSAN, Microsoft Azure Local, SAP HANA | Not listed |
| Input / Output - DOM | 2 SuperDOM (Disk on Module) ports | Not listed |
| Input / Output - USB | 2 USB 3.0 ports (rear), 1 USB 3.0 port (front) | 2 USB 2.0 ports (front) |
| Chassis - Form Factor | 1U Rackmount | 2U Rackmount |
| Front Panel - Buttons | Power On/Off, UID button | Power On/Off, Power On/Off , UID button |
| System Cooling - Fans | Up to 8x 4cm heavy duty fans with optimal fan speed control | Up to 6 Hot-swappable 60x60x56mm Fan(s) |
| On-Board Devices - NVMe | NVMe; RAID 0/1/5/10 support | NVMe; RAID 0/1/5/10 support(Intel® VROC RAID key required) |
| PC Health Monitoring - CPU | 7 +1 Phase-switching voltage regulator; Monitors for CPU Cores, Chipset Voltages, Memory | Monitors for CPU Cores, Chipset Voltages, Memory |
| Default Power Supply - +12V | Max: 66.7A / Min: 0A (100Vac-127Vac), Max: 100A / Min: 0A (200Vac-240Vac), Max: 100A / Min: 0A (200Vdc-240Vdc) | Max: 83A / Min: 0A (100Vac-127Vac), Max: 150A / Min: 0A (200Vac-220Vac), Max: 165A / Min: 0A (220Vac-230Vac), Max: 166A / Min: 0A (230Vac-240Vac) |
| System Cooling - Air Shroud | 2 Air Shrouds | 4 Air Shrouds |
| Default Power Supply - Input | 800W: 100-127Vac / 50-60Hz, 1200W: 200-240Vac / 50-60Hz, 1200W: 200-240Vdc / 50-60Hz (for CCC only) | 1000W: 100-127Vac / 50-60Hz, 1800W: 200-220Vac / 50-60Hz, 1980W: 220-230Vac / 50-60Hz, 2000W: 230-240Vac / 50-60Hz, 2000W: 220-240Vac / 50-60Hz (for UL only), 2 |
| Default Power Supply - 12V SB | Max: 2.1A / Min: 0A | Max: 3.5A |
| Chassis Dimensions and Weight - Depth | 29.1" (739 mm) | 22.6" (574 mm) |
| Chassis Dimensions and Weight - Width | 17.2" (437 mm) | 17.2" (436.88 mm) |
| Chassis Dimensions and Weight - Height | 1.7" (43 mm) | 3.5" (88.9 mm) |
| Chassis Dimensions and Weight - Weight | Gross Weight: 41 lbs (18.6 kg), Net Weight: 26.5 lbs (12.2 kg) | Gross Weight: 47.4 lbs (21.5 kg), Net Weight: 34.4 lbs (15.6 kg) |
| Chassis Dimensions and Weight - Package | 7.99" (H) x 23.81" (W) x 37.4" (D) | 9.7" (H) x 23.5" (W) x 36.9" (D) |
| On-Board Devices - Network Connectivity | 2 RJ45 10GBASE-T with Intel® X710-AT2 (optional), 2 RJ45 10GBASE-T with Intel® X710-TM4 (optional), 2 SFP+ 10GbE with Intel® X710-TM4 (optional), No NIC option | Via AIOM |
| Operating Environment - Environmental Spec. | Operating Temperature: 10°C to 35°C (50°F to 95°F), Non-operating Temperature: -40°C to 60°C (-40°F to 140°F), Operating Relative Humidity: 8% to 90% (non-conde | Operating Temperature: 5°C to 35°C (41°F to 95°F), Non-operating Temperature: -40°C to 70°C (-40°F to 158°F), Operating Relative Humidity: 8% to 90% (non-conden |
| Chassis Dimensions and Weight - Available Color | Black Front & Silver Body | Silver |
| Drive Bays / Storage - Drive Bays Configuration | Default: Total 12 bays; 12 front hot-swap 2.5" NVMe/SAS*/SATA drive bays | (*SAS support may require additional storage controller and/or cables, please see the | Default: Total 6 bays; 6 front hot-swap 2.5" NVMe/SAS*/SATA drive bays | (*SAS support may require additional storage controller and/or cables, please see the o |
| Expansion Slots - PCI-Express (PCIe) Configuration | Default: 1 PCIe 4.0 x16 LP slot, 1 PCIe 4.0 x16 LP slot, 2 PCIe 4.0 x16 FH/10.5"L slots | Default: 2 PCIe 4.0 x8 FH/10.5"L slots, 2 PCIe 4.0 x8 FHHL slots, 2 PCIe 4.0 x16 AIOM slots (OCP 3.0 compatible); Option A: 1 PCIe 4.0 x16 FH/10.5"L slot, 1 PCI |
| CPU-GPU Interconnect | Not listed | PCIe 4.0 x16 CPU-to-GPU Interconnect |
| GPU-GPU Interconnect | Not listed | PCIe |
| Drive Bays / Storage - M.2 | Not listed | 2 M.2 NVMe/SATA slots (M-key 2280/22110) |
Shaded rows differ. Rows are matched by their label, so two makers' names for the same figure can sit on separate rows; hover a value to see its maker's own label where it differs.