nVent CX121 CDU Rated 2.3 MW, Production Starts Late 2026
nVent will start production of its 2.3 MW CX121 modular CDU late 2026 and is taking pre-orders at SC26, but the 2.3 MW is a vendor maximum with no rack, flow or temperature data.
2 min read

nVent's CX121 CDU: 2.3 MW maximum operating performance and production from late 2026, both vendor claims.
Graphic: Voltgrid News
nVent Electric plc said on Nov. 16 that it will begin production of its CX121 modular coolant distribution unit (CDU) late this year, with a maximum operating performance of 2.3 megawatts, and open pre-orders at the SC26 supercomputing show in Chicago.
The company said in its release that it has already accepted "significant" pre-orders, without giving a number or naming a customer. It also said it has deployed more than four gigawatts of liquid cooling to date. The release describes the CX121 as modular, so operators can configure it to their application, and claims "best-in-class" flow rates but gives no flow figure.
nVent also showed an 800-volt DC power rack under its MAVERICK brand, shown alongside an IT rack at SC26. The company said the rack integrates power conversion, protection and controls to turn existing AC supply into 800 V DC, so high-density AI computing does not need a facility-wide power redesign.
What 2.3 MW means for a hall
A CDU is the heat exchanger that sits between the server cold plates and the building's water loop. A 2.3 MW rating is the vendor's ceiling, and nVent's release does not say whether it counts heat removed or at what supply temperature. Voltgrid has therefore not converted it into a rack count. For scale, Trane's CDU rated up to 2.5 MW was recently set against Vera Rubin racks at 227 kW each, which shows how few racks one large unit can serve at that density.
nVent rates the CX121 at up to 2.3 MW maximum operating performance, a vendor claim; the basis of the rating is not stated.
Graphic: Voltgrid News
Pairing a large CDU with a rack-level 800 V DC supply matters because both set the limit on rack density: one carries the heat out, the other carries the power in. nVent sells both, and said its total data-center content opportunity has grown to about $2 million per megawatt after the Maverick Power acquisition, a company estimate.
Maverick Power and the wider portfolio
nVent said it closed the Maverick Power acquisition last month. Data Centre Review reported on Aug. 25 that nVent agreed to pay $1.75 billion, up to $2.3 billion if Maverick meets 2027 and 2028 performance targets, for low- and medium-voltage switchgear, switchboards and integrated modular power systems. The trade outlet said nVent's second-quarter 2026 sales were $1.47 billion, up 53% from a year earlier, and that nVent announced a 160,000 sq ft Minnesota liquid cooling plant in July.
The SC26 release lists further items. An OCP-compliant liquid-to-air CDU under Project Brazos is meant to let liquid-cooled AI racks run in air-cooled halls without facility water or chilled-water plant. nVent's rear door heat exchanger is part of the AMD Helios rack-scale design under a collaboration announced earlier. The company uses DSX-qualified PG25 coolant for single-phase cold-plate loops with NVIDIA.
Other vendors are also pushing multi-megawatt units. Voltgrid covered Daikin Applied's 60 MW D60-W design for NVIDIA DSX racks on Nov. 11, and Vertiv's SmartIT bundle in October, which also gave no per-rack figure.
What is not confirmed yet
The 2.3 MW figure is nVent's own claim, and the only source for it is the company's release; no independent test or datasheet has been published. It is not stated whether the rating is heat removed, the coolant supply and return temperatures, the flow rate, or the number of racks one unit serves. The release gives no price, order count or delivery date beyond "late this year". The 800 V DC rack comes without a power rating or availability date.