Compal SC26 Liquid-Cooled Rubin Rack Holds 72 GPUs in Nine Servers
Compal's liquid-cooled SC26 rack holds 72 Rubin GPUs in nine servers but states no rack kW, CDU size or coolant temperature. Our estimate, not Compal's rating: about 216 kW.
2 min read

NVIDIA's HGX platform image from its product page. It is the platform under Compal's SC26 rack, not a photo of Compal's rack.
Image: NVIDIA
Source · Press image from the NVIDIA website, used for news reporting.
Compal Electronics showed a direct-liquid-cooled Rubin rack at Supercomputing 2026 (SC26) in Chicago on Nov. 18 that holds up to nine OG231-2-L1 servers and a maximum of 72 NVIDIA Rubin GPUs, according to its release on PR Newswire.
Each server carries eight Rubin GPUs and NVIDIA NVLink 6, Compal said. The rack combines direct liquid cooling (DLC), rack-level power infrastructure, centralized system management and leak protection, built on NVIDIA's HGX Rubin NVL8 platform. Compal is also showing a Vera CPU rack, the OX130-8N-L1, with up to 32 compute trays and 256 Vera CPUs, each tray pairing eight CPUs with one BlueField-4 data processing unit (DPU).
What the release leaves out
The release gives no kW per rack, no coolant supply temperature, no coolant distribution unit (CDU) capacity and no share of heat removed by liquid. Compal does not say who supplies the cold plates, manifolds or CDU. The performance figures it quotes, such as up to 400 petaflops of NVFP4 inference per eight-GPU system, are NVIDIA's published numbers, not Compal measurements.
Our arithmetic: roughly 216 kW of servers
An earlier Compal page, from Computex on June 1, says the OG231-2-L1 sustains approximately 24 kW of system power under its DLC design. Nine servers at that figure come to about 216 kW per rack. This is our multiplication of a vendor's per-server number, not a rack rating from Compal, and it leaves out power shelves, switches and fans. Treat it as a floor for the electrical load a hall would have to feed and cool.
Compal's rack holds up to nine servers and a maximum of 72 GPUs; the 216 kW figure is our estimate from 24 kW per server, not a Compal rating.
Graphic: Voltgrid News
Where it sits against earlier cooling coverage
Voltgrid reported on Oct. 28 that Vertiv's SmartIT bundle also shipped without a kW per rack or coolant temperature. Daikin Applied's D60-W design, reported on Nov. 11, is the contrast: it states a 60 MW scale and a 92% liquid share for Vera Rubin NVL72 racks. Compal's rack is a server integrator's product, so the facility side, meaning CDUs and heat rejection, remains the buyer's problem until Compal or a partner publishes it.
HPCwire's SC26 preview, published Nov. 14, lists Compal's OG231-2-L1 alongside its OG430-2-L1 direct-liquid-cooled server on NVIDIA's HGX B300 platform and an air-cooled SGX30-2. It carries no cooling figures for Compal either.
Compal has not given a shipping date, a price or named customers for either rack. It has not stated a rack power rating or the facility water temperature the rack accepts. Until it does, the 72-GPU, nine-server layout is the only hard rack-level fact, and the cooling load stays an estimate built from a June server figure.
Sources
- Published
- Sources
- 2 cited